·Î±×ÀÎȸ¿ø°¡ÀÔ

¼­¹ö(Server)
³×Æ®¿öÅ©Àåºñ
PC¡¤¿öÅ©½ºÅ×À̼Ç
³ëÆ®ºÏ / ÅÂºí¸´ PC
¸ð´ÏÅÍ,ÇÁ¸°ÅÍ,½ºÄ³³Ê
HDD/SDD/¸Þ¸ð¸®
°ø±¸¡¤»ê¾÷¿ëÇ°
»ç¹«±â±â
¹æ¼Û/¿µ»óÀåºñ, ºöÇÁ·ÎÁ§ÅÍ
CCTV¡¤DVR(¹æ¹ü)
À½Ç⡤¾ÚÇÁ¡¤¿Àµð¿À
¼¼´Ü±â/°è¼ö±â/õ°ø±â
POS(Æ÷½º) / ¹ÙÄÚµå
»ýÈ°°¡Àü
Á¶ ¸í
ÇǺÎ/¹Ì¿ë ±â±â
±âŸ
ÀÚ·á½Ç
°øÁö»çÇ×
°¡°ÝÈïÁ¤ÇÏ±â ¹× ¹®ÀÇ
 043-881-1749

 070-7576-4066

 010-5252-1231
ÆòÀÏ 09:00~18:00
±¹¹Î 479002-01-224892
³óÇù 044-12-105941
¿¹±ÝÁÖ: ¹é¿µÈÆ
 
 
ºñ¹Ð¹øÈ£ È®ÀÎ ´Ý±â
°ø±¸¡¤»ê¾÷¿ëÇ° > ÃøÁ¤¿ë°ø±¸ > Intellix SM110 ´Ü»ó Àü·Â·®°è / Single Phase Electricity Meter »õ Á¦Ç°

Intellix SM110 ´Ü»ó Àü·Â·®°è / Single Phase Electricity Meter »õ Á¦Ç°
ÆǸŰ¡°Ý : 129,000¿ø
Àû¸³±Ý¾× : 1%
ÃÑ »óÇ° ±Ý¾× 0 ¿ø
³²Àº¼ö·® : 3°³
¹è¼ÛÁ¶°Ç : (»óÇ°¹«°Ô)
 
   

¹è¼Ûºñ´Â ¹«°Ôº° Â÷µî Àû¿ëµË´Ï´Ù.(3,000~80,000¿ø)
Àå¹Ù±¸´Ï¿¡ ´ã°Å³ª, ³×À̹öÆäÀÌ ±¸¸Å¹öÆ°À» ´©¸£¸é Á¤È®ÇÑ ¹è¼Ûºñ°¡ ³ª¿É´Ï´Ù.
»óÇ°¿¡ µû¶ó¼­´Â ¿©·¯°³¸¦ ¹­À½¹è¼ÛÇÏ´Â °Íº¸´Ù °³º°±¸¸ÅÇÏ´Â °æ¿ìÀÇ ¹è¼Ûºñ°¡ ´õ Àú·ÅÇÒ ¼ö ÀÖ½À´Ï´Ù.
¹è¼Ûºñ°¡ °ú´ÙÇÏ°Ô »êÁ¤µÉ °æ¿ì ÀüÈ­·Î ¹®ÀÇÁÖ¼¼¿ä.

°¡°Ý ÀýÃæ À§ÇÑ ÀüÈ­¹®ÀÇ(043-881-1749) ȯ¿µÇÕ´Ï´Ù!

¹Ì¸® ¼³¸íµÇÁö ¾ÊÀº ±â´É»ó ÇÏÀÚ°¡ ÀÖ´Ù¸é ÀúÈñ ºñ¿ëÀ¸·Î ±³È¯ ¶Ç´Â ¹ÝÇ°¡¤È¯ºÒÇص帳´Ï´Ù.
(¹°Ç°¼ö·ÉÀϺÎÅÍ 30ÀÏ À̳»)

We Ship Worldwide! We accept PayPal payments!
Please contact us via morninghillatebay@gmail.com for quotation.

´Ü»ó Àü·Â·®°è, »õ Á¦Ç° ÀÔ´Ï´Ù.

½Ç Á¦Ç°À» Á÷Á¢ ÂïÀº »çÁø°ú »ó¼¼ ¼³¸íÀ» º¸½Ã°í

±Ã±ÝÇÑ Á¡Àº ¹®ÀÇÇØÁÖ¼¼¿ä.

 

* Phases : Single phase, two wire

* Measuring elements : Single element

* Current : 20 A ~ 100 A

* Nominal voltage : 230 V ¡¾ 20%

* Frequency : 50 Hz or 60 Hz

* Accuracy : Class 1 per IEC¢ç 62053?21 (active energy)
Class 2 per IEC 62053?23 (reactive energy)

* Power consumption : ~1 W without AMR/AMI module

* Relays : 100 A supply disconnect

* LCD : 6 main characters
11.5 mm high x 5.6 mm wide
Decimal point selectable per display

* Ports : RS232 (option)

* Advanced Meter Infrastructure : Integrated with Nuri Telecom AMI module
(ask your local sales representative for more information about compliant AMI technologies)

* Terminal cover : Standard or extended length option

* Optical port : Per IEC 61107 (physical and electrical requirements) and
ANSI¢ç C12.18 (communication protocol)
9,600 bps communication rate

* Data storage : Non-volatile memory
200 days load profile for 1 channel at 30-minute intervals

* Pulse outputs : One optical per IEC 62052?11; one mechanical
per IEC 62053?31

* Operating temperature : 25¡ÆC to +60¡ÆC
40¡ÆC to +60¡ÆC (option)

* Humidity : 95% non-condensing

* Ingress protection : IP54

* Weight : ~1.0 kg with disconnect relay

 


* Residential Class Meter Technology

The Intellix SM110* from GE is a multi-function, single phase
electronic meter for residential applications. The meter¡¯s
advanced design is a powerful combination of accuracy,
affordability, and reliability. Offering features beyond basic energy
metrology, including time of use and load profile recording, the
SM110 is ideal for your most demanding residential metering
applications.

 

* Flexible Recording

The SM110 may be configured for various metering needs:
demand-only metering, demand/load profile (LP) metering, TOU
or TOU/demand metering, TOU or TOU/demand meter with load
profile metering.

 

* Remote Connect/Disconnect

The SM110 is available with an integrated 100 A rated relay for
remote disconnection and reconnection of supply to provide
utilities with the ability to manage situations such as changing
of tenants at a premise or management of customers that have
failed to pay required bills.

 

* Summations

The SM110 supports up to two summations from the following
measurements: delivered-only kWh; received-only kWh; delivered
+ received kWh; delivered/received kWh; lagging-only kvarh;
leading-only kvarh; lagging + leading kvarh; lagging/leading
kvarh; phasor apparent kVAh; and line-to-neutral voltage.

 

* Time Of Use

The SM110 provides up to four distinct TOU tiers, allowing timeof-
use energy and demand values to be calculated for specific
time periods, in addition to the overall energy and demand
calculations. The meter also supports up to four seasons.
Each season can have up to three day-types and one holiday
day-type. The meter can store a total of 80 distinct tier switches.

 

* Calendar

The SM110 includes a calendar with up to 50 programmable
dates for specifying when daylight savings time changes, season
changes, self-reads, demand resets, and holidays are to occur.

 

* Load Profile

The SM110 supports two channels of load profile recording with
sufficient memory to store 200 days of single channel data at
30-minute intervals.

 

 

 



¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Á¶È¸
 

»óÈ£¸í : ¸ð´×Èú »ç¾÷ÀÚµî·Ï¹øÈ£ : 132-20-76708 132-20-76708 Åë½ÅÆǸž÷½Å°í¹øÈ£ : Á¦2007-377È£[»ç¾÷ÀÚÁ¤º¸È®ÀÎ] ´ëÇ¥ : ¹é¿µÈÆ  [ÀÌ¿ë¾à°ü] °³ÀÎÁ¤º¸Ãë±Þ¹æħ °³ÀÎÁ¤º¸´ã´çÀÚ : ¹é¿µÈÆ
»ç¾÷Àå¼ÒÀçÁö : ÃæûºÏµµ À½¼º±º »ý±Ø¸é Áß¿ø´ë·Î 45
ÀüÈ­: 043-881-1749,  Æѽº: 031-624-1749, E-Mail: morninghill@hotmail.com

Copyright ¨Ï ¸ð´×Èú MorningHill All Rights Reserved.